WhisperPower Equipment
AGM Battery 12 V - 55 Ah
12 V 55 Ah AGM (VRLA) maintenance-free battery for marine, mobile and solar systems, inverters, pumps, winches and engine starting.
Description
The WhisperPower AGM Battery 12 V – 55 Ah (part number 40290060) is a maintenance-free VRLA (valve-regulated lead-acid) battery that needs little ventilation and can be installed in any orientation. It suits marine, mobile and solar energy systems, medium-sized inverters, DC installations, pumps and winches, and can also be used as a starter battery.
Technical data
- Nominal: 12 V, 55 Ah (C10); 6 cells
- Capacity: 58.6 Ah (20 h), 55.0 Ah (10 h), 44.5 Ah (5 h); 92 min at 25 A
- Float charge: 13.60–13.80 VDC; absorption: 14.25–14.60 VDC at 25 °C
- Max recommended charge current: 40–50% of capacity
- Inrush current (5 s, 25 °C): 550 A
- Cycle life at 80% discharge: 400
- Self-discharge: <3% per month at 25 °C; internal resistance approx. 6.0 mΩ
- Dimensions: 229 × 138 × 210 mm; weight 18.0 kg; M6 stainless terminals
Specifications
| 40290060 | AGM Battery 12 V - 55 Ah |
|---|---|
| Length x width x height | 229 × 138 × 210 mm (9" x 5.4" x 8.3" inch) |
| Weight ± 10% | 18.0 kg / 39.7 lb. |
| Nominal capacity | 55 Ah |
| C10* or C20 | C10 |
| Nominal voltage | 12,0 VDC |
| Terminal type | M6 rvs |
| Number of cells | 6 |
| Constant charge voltage (IU, float) | 13.60 .. 13.80 VDC at 25oC |
| Cyclic charge voltage (IUU, absorption) | 14.25 .. 14.60 VDC at 25oC |
| Maximum recommended charge current (higher possible) | 40 to 50% of nominal capacity |
| Temperature ratio | -4mv/cel/°C |
| Discharge voltage | 1.75 VDC @ (A) ≤ 0.2°C • 1.70 VDC @ 0.2°C (A) ≤ 1.0°C |
| Full discharge (100% DOD) | 1.65 VDC @ (A) ≥ 1.0°C |
| Nominal 25°C | UP TO 1.75 VDC/CEL |
| 20 hours discharge | 58.6Ah |
| 10 hours discharge | 55.0 Ah |
| 5 hours discharge | 44.5 Ah |
| Peukeurt Coefficient | 1.21<P<1.24 |
| Usage at 25 A discharge | 92 min |
| Self discharge | Less than 3% per month at 25°C |
| Storage time | AGM batteries can be stored for up to 6 months at 25°C, recommended to charge before use |
| Inrush current at 25°C (5s) | 550 A |
| Cyclic life at 80% discharge | 400 |
| Internal resistance (approx.) | 6,0m Ω |
More from WhisperPower
- WhisperPower Supreme 12 VDC - 40 A
- WhisperPower AC PowerCube 24 VDC – 14000 VA
- WhisperPower AC PowerCube 24 VDC – 7000 VA
- WhisperPower AGM battery 12 V - 100 Ah
- WhisperPower AGM Battery 12 V - 145 Ah
- WhisperPower AGM Battery 12 V - 200 Ah
- WhisperPower AGM Battery 12 V - 260 Ah
- WhisperPower AGM Battery 12 V - 80 Ah
- WhisperPower Alternator 12 V
- WhisperPower Battery Equalizer 24 VDC
- WhisperPower DC PowerCube 24 VDC - 150 A
- WhisperPower DC PowerCube 48 VDC - 80 A
Featured products
All products →Equipment
Variable Speed ID Plater
Variable-speed drive with polypropylene flow chamber for plating inside diameters, conducting plating current up to 150 amp.
Equipment
100 CFM Breathing Air Filtration Panels
Wall-mount three-stage breathing air filtration panels, 100 CFM with four outlets, plain or with integrated CO-GUARD, ProAir/MedAir 2200 or Matrix Air monitors.
Device / Instrument
Tank Gauging & Level Monitoring Systems Services
Onboard calibration, testing and commissioning of ullage, temperature and interface gauging, water ingress detection and integrated cargo monitoring systems (ICMS), to class, IMO and terminal vetting standards.