ELIN Motoren Inspection, Survey & Testing
Test field and diagnostics for electric motors and generators
Electrical test field for synchronous and asynchronous machines (up to 15,000 V, 6 MW full-load direct-coupled) plus mobile diagnostics including loss factor and partial discharge measurement.
Description
ELIN Motoren's test field and diagnostics service performs electrical tests on all synchronous and asynchronous machines, from routine to system tests, at its test facility or worldwide with a mobile diagnostic system.
Test field data
- Total area: about 1,000 m²
- Supply voltages: up to 15,000 V
- Full load tests: up to 6 MW directly coupled
- Substitute test procedure for asynchronous machines up to 15 MW
- Substitute test procedure for synchronous machines up to 50 MVA
Machine diagnostics
Diagnostics detect insulation and surface faults in rotating electrical machines early, such as delamination, voids (shrink holes), contamination, changes to corona protection and humidity.
- Loss factor (tan delta) measurement – a baseline at manufacture or commissioning; deviations in repeat measurements indicate changes in the dielectric
- Partial discharge measurement – locates insulation defects and quantifies discharge size and charge; repeat measurements during revisions track changes in the insulation system
- Supports condition-based maintenance and budget planning
More from ELIN Motoren
Featured services
All services →Rental / Leasing
Ship repair yard (time-based leasing)
Fully equipped ship repair yard available for time-based leasing, with an on-site operations centre controlling daily ship repair activities, ship lifts and wet and dry berths.
Other service
Dockage and Moorings
Seasonal and transient dockage and moorings at the Crosby Yacht Yard marina in Osterville, Cape Cod, with a fuel dock on site.
Consulting
Technical Support
Support across the selective plating process, from process and application development to troubleshooting and testing procedures.
Similar services